Home >> Application >> By Standard >> ASTM >> ASTM D >> ASTM D2992 Fiberglass Pipe Hydrostatic Test for Obtaining Hydrostatic or Pressure Design Basis

ASTM D2992 Fiberglass Pipe Hydrostatic Test for Obtaining Hydrostatic or Pressure Design Basis

Share:

ASTM D2992 Hydrostatic Pressure Design Basis Tester for GRP Fiberglass Pipe and Fittings | UnitedTest

UnitedTest manufactures ASTM D2992 hydrostatic pressure rupture test machines for fiberglass GRP pipe and fittings. Generate short-term pressure rupture data for statistical extrapolation to calculate HDB and PDB for 50-year design life validation.


ASTM D2992 establishes a standardized statistical extrapolation practice rather than a simple pass-or-fail test for fiberglass glass-fiber-reinforced thermosetting resin (GRP) pipe and fittings. The standard outlines procedures for collecting short-term pressure rupture test data, performing log-log regression analysis, and extrapolating results to a 50-year service life to establish the Hydrostatic Design Basis (HDB) or Pressure Design Basis (PDB) for specific pipe products and production processes. UnitedTest provides reliable hydrostatic pressure rupture test systems complying with ASTM D2992 for GRP pipeline material qualification, product certification and long-term design performance assessment.


Test Principle:

Fiberglass pipe fails by slow, progressive damage (resin microcracking → weeping → leak) under sustained or repeated internal pressure. The relationship between hoop stress (or internal pressure) and time/cycles to failure is approximately a straight line on a log-log plot:

S=P*(D-t)/2t

where S = hoop stress, P = internal pressure, D = average reinforced outside diameter, t = minimum reinforced wall thickness (the ISO hoop-stress equation).

The practice requires that the failure points span three or more logarithmic decades of time, fits a least-squares linear regression in log₁₀–log₁₀ space (Annex A1), and then uses the lower 95 % confidence / prediction limits — not the mean line alone — to set the design basis. Two physical bases are used:

Stress basis (HDB) — for straight, hollow cylindrical pipe where hoop stress can be calculated. Using stress instead of pressure normalizes away specimen geometry, so one size of pipe can be used to rate all sizes made by the same process.

Pressure basis (PDB) — for fittings, joints, and complex shapes where the stress field is too complicated to compute hoop stress.


Specific Test Method: 


Procedure A — CyclicProcedure B — Static
Governing underlying test methodASTM D2143 (Cyclic Pressure Strength of Reinforced, Thermosetting Plastic Pipe)ASTM D1598 or F948 (Time-to-Failure under Constant Internal Pressure)
LoadingCycling internal pressure at 25 cycles/minConstant internal hydrostatic pressure
Measured responseCycles to failureHours to failure
Temperature controlHot liquid circulated through the specimen, or controlled hot-air environmentControlled-temperature water bath, controlled air environment, or circulated temperature-controlled fluid
Design life points150 × 10⁶ or 657 × 10⁶ cycles (= 50 yr at 25 cpm)100 000 h or 438 000 h (= 50 yr)
Minimum data points≥ 18 failure points per temperature≥ 18 failure points per temperature
Pressure toleranceper D2143± 1 % of set pressure


Test Specimen Information:

  1. Specimen type: pipe segments, fittings, or pipe‑fitting assemblies with field‑typical joints; joints shall replicate real‑service piping construction.

  2. Geometry limitation: HDB evaluation is valid for pipe with outer‑diameter‑to‑reinforced‑wall‑thickness ratio ≥ 10:1 (thin‑wall pipe theory basis).

  3. Specimen quantity: minimum 18 valid failure data points per temperature for each procedure.

  4. Non‑failed specimens: specimens surviving > 15 000 000 cycles (Procedure A) or > 10 000 h (Procedure B) may be treated as censored “virtual failure” points for regression analysis, subject to statistical pass criteria.

ASTM D1598 test for long-term hydrostatic pressure of plastic pipe


Test Equipment required for the ASTM D2992 Fiberglass Pipe Hydrostatic Test for Obtaining Hydrostatic or Pressure Design Basis

Pipe Hydrostatic Pressure Test System

Hydraulic pump / pressure intensifier with regulators, solenoid valves and multi-station manifolds; 

capable of cycling at 25 cycles/min (Procedure A) or holding constant pressure within ±1 % for up to tens of thousands of hours (Procedure B).

Failure / leak detection — visual observation of weeping, or electronic detection (e.g., conductivity/resistance-based leak detectors; D2143-type detectors trigger on a resistance drop or visible leakage).

Statistical software implementing the mandatory least-squares functional-relationship analysis (validated against the worked example to within ±0.1 %).

Enclosures

either free-end (sealed caps; pressure produces hoop + longitudinal stress, hoop = 2 × longitudinal) or restrained-end (tie rod through the specimen or an external frame; hoop + radial stress only). 

Selection depends on the stress state and joint type of the intended piping system.

Temperature conditioning system

circulating heated-liquid loop, controlled-temperature water bath, or controlled-temperature air chamber, holding the test liquid within ±5 °F (3 °C).


General Test Procedures of ASTM D2992 Fiberglass Pipe Hydrostatic Test for Obtaining Hydrostatic or Pressure Design Basis:

  1. Select end‑closure type (restrained‑end or free‑end) according to real‑service stress state.

  2. Prepare pipe / fitting / assembly specimens; measure dimension per ASTM D3567.

  3. Mount specimens to pressure test equipment, set target temperature and environment medium.

  4. Apply multiple levels of cyclic pressure (Procedure A, 25 cycles/min) or constant static pressure (Procedure B). Record cycles‑to‑failure or time‑to‑failure for each specimen, distinguish real failure vs invalid end‑leak test.

  5. Collect minimum 18 valid failure points covering multiple logarithmic decades of time/cycles.

  6. Process dataset by Annex A1 mandatory least‑squares regression: compute slope, intercept, correlation coefficient r, 95 % confidence and prediction limits. Reject dataset if statistical criteria fail.

  7. Extrapolate regression line to specified long‑term target (cycles or hours) to get LTHS / LTHP. Assign HDB / PDB category per standard tables.

  8. For material‑/process‑changed products: perform re‑confirmation screening test with ≥ 6 specimens and judge pass/fail per 95 % confidence‑interval rules.

  9. Multiply HDB/PDB by project‑selected service design factor to get HDS/HDP, then calculate pipe pressure rating.


The Full Terminology Chain

LTHS (long-term hydrostatic strength)The hoop stress extrapolated to cause failure at a specified life (150 × 10⁶ or 657 × 10⁶ cycles for Procedure A; 100 000 or 438 000 h for Procedure B)
LTHP (long-term hydrostatic pressure)Same, expressed as internal pressure instead of stress
HDBLTHS categorized into an ISO 3 / R10 preferred-number series
PDBLTHP categorized into an ISO 3 / R10 series
Service design factorA number ≤ 1.00 chosen by the design engineer (ASTM deliberately does not prescribe it)
HDS / HDPHDB × service design factor / PDB × service design factor
PR (pressure rating)The continuous pressure the component can safely carry


Related Standards: 

ASTM D2143 

Standard Test Method for Cyclic Pressure Strength of Reinforced, Thermosetting Plastic Pipe

ASTM D2992Practice for Obtaining Hydrostatic or Pressure Design Basis for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings
ASTM D1598Time-to-failure under constant internal pressure (Procedure B)
ASTM D1599short-time hydraulic pressure (used to verify scaling of fittings/joints)
ISO 1167Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure
AWWA C950fiberglass pressure pipe (US water-works practice)
ISO 14692 Petroleum and natural gas industries - Glass-reinforced plastics (GRP) piping
ISO 9080Plastics piping and ducting systems - Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
ASTM D2837Obtains HDB/PDB for thermoplastic plastic pipe (similar statistical logic but for non‑reinforced thermoplastics, not fiberglass thermoset composites)


Industry fields of application

Fiberglass/GRP piping is chosen where corrosion resistance, light weight and long life matter. D2992-derived HDB/PDB values feed directly into product standards and project specifications in:

  • Chemical and petrochemical process piping — acid, caustic, brine and solvent lines (RTRP with resin liners).

  • Oil & gas — produced-water, seawater injection, firewater and downhole/flowline GRP systems (aligned with ISO 14692 qualification).

  • Water and wastewater — potable water transmission, sewage force mains, desalination (RPMP large-diameter pipe).

  • Power generation — cooling water, FGD (flue-gas desulphurization) slurry, ash-handling lines.

  • Marine & offshore, mining and pulp & paper — highly corrosive or abrasive slurries.

  • Buried/non-pressure or low-pressure installations — where the alternative strain-basis HDB (initial strain vs. time-to-failure, typically for 0–250 psig buried designs) is used instead of the stress-basis HDB of this practice


Keywords: ASTM D2992 hydrostatic pressure tester, GRP pipe pressure rupture test machine, fiberglass pipe hydrostatic design basis test, HDB PDB test equipment for FRP pipe, glass fiber reinforced thermoset pipe pressure test, 50 year design life extrapolation test, log-log regression pressure rupture test, fiberglass fitting hydrostatic tester, GRP pipeline certification testing instrument, UnitedTest ASTM D2992 testing machine, thermosetting resin pipe pressure burst tester

Related products and device

ASTM D2992 Pipe Hydrostatic Pressure Testing Machine

hydrostatic pressure testing machine is designed according to ISO 1167, ASTM D1598, ASTM D1599. Under a stipulated constant hydrostatic pressure force, keeping provision time; or inside the pipe, apply a constant and rapid hydraulic pressure to make the specimen broken in a short period time, check the max. pressure force, then calculate the ring stress.

ASTM D2992 hydrostatic pressure tester, GRP pipe pressure rupture test machine

Constant temperature water tank is a crucial piece of equipment for hydrostatic pressure tests, particularly for long-term and burst tests. It is designed to maintain a constant pressure and temperature during testing, which is essential for accurately assessing the strength and durability of pipe.

ASTM D2992 End cap of pipe pressure test

Stainless Steel End Caps For Pipe Hydrostatic Pressure and Burst Testing are designed for internal hydrostatic pressure testing of pipes and fittings. It is used to seal the sample in order to generate internal pressure in the sample, with the characters: ISO 1167 Type A structure.

Related Standard

ASTM D1599 Pipe short-time hydraulic burst pressure test –

ASTM D1599 is titled "Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings." It is a fundamental short-term, destructive pressure test used to determine the ultimate failure pressure (often called the "burst pressure") of thermoplastic pipe, tubing, or fittings under rapidly applied internal pressure at a specified temperature. Typically completed within 60–70 seconds, mainly for quality control and short-term design validation. 

ASTM D1598, D1599 Plastic Pipe Constant or short time pressure testing methods –

ASTM D1598: Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure.

ASTM D1598 test method covers the determination of the time-to-failure of both thermoplastic and reinforced thermosetting/resin pipe under constant internal pressure.This test method provides a method of characterizing plastics in the form of pipe under the conditions prescribed.


ASTM D1599: Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings.

ASTM D1599 test method establishes the short-time hydraulic failure pressure of thermoplastic or reinforced thermosetting resin pipe, tubing, or fittings. Data obtained by this test method are of use only in predicting the behavior of pipe, tubing, and fittings under conditions of temperature, time, method of loading, and hoop stress similar to those used in the actual test. They are generally not indicative of the long-term strength of thermoplastic or reinforced thermosetting resin pipe, tubing, and fittings


ISO 1167 Thermoplastics pipes resistance to internal pressure test –

ISO 1167: 2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids -- Determination of the resistance to internal pressure.

ISO 1167 test method specifies a general test method for determining the resistance to internal hydrostatic pressure at a given temperature of thermoplastics pipes, fittings and piping systems for the transport of fluids. The method accommodates water-in-water, water-in-air and water-in-liquid tests. It defines uniform hydrostatic pressure testing to evaluate short-term and long-term pressure-bearing durability of thermoplastic fluid-transport piping systems.


Hydrostatic pressure testing is a valuable method for assessing the strength and integrity of pressurized systems, ensuring that they can meet operational demands without failure. Hydrostatic pressure testing can evaluate these items by filling pipelines, tanks, or containers with water before pressure is applied to detect any potential leaks or issues. 

Hydrostatic pressure tester is critical across multiple industries, from pipeline engineering to industrial piping. It helps prevent costly failures or leaks by verifying whether the system can safely reach the specified pressure levels.

ISO 9080 Long Term Hydrostatic Pressure Test for Thermoplastic Pipe –

ISO 9080 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation.

ISO 9080 specifies a statistical extrapolation method (Standard Extrapolation Method, SEM) to predict long‑term hydrostatic performance of thermoplastic pipe materials, instead of conducting multi‑decade real‑time ageing tests.

ISO 4437-1 Tensile, Hydrostatic pressure test for Plastics PE piping systems for the supply of gaseous fuels –

ISO 4437-1:2024 Plastics piping systems for the supply of gaseous fuels — Polyethylene (PE) Part 1: General

ISO 4437-1:2014 specifies the general properties of polyethylene (PE) compounds for the manufacture of pipes and fittings intended to be used for the supply of gaseous fuels. It also specifies the test parameters for the test methods referred to in this International Standard.   

ASTM D1598 test for long-term hydrostatic pressure of plastic pipe –

ASTM D1598 Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure. It is a fundamental test method used to determine the long-term hydrostatic strength and resistance of thermoplastic pipe by applying a constant internal pressure until the pipe specimen fails (ruptures). Which is critical for establishing hydrostatic design basis and ensuring long-term pipeline reliability.

ASTM D2143 Cyclic Pressure Test for Reinforced Thermosetting Plastic Pipe –

ASTM D2143 Standard Test Method for Cyclic Pressure Strength of Reinforced, Thermosetting Plastic Pipe

ASTM D2143 determines the failure characteristics of reinforced thermosetting plastic pipe under cyclic internal hydraulic pressure — i.e., how many pressure cycles a pipe survives at a given pressure/stress level. Its real purpose is not to pass/fail a single pipe, but to generate the stress‑vs‑cycles‑to‑failure data points that feed the regression analysis in ASTM D2992 Procedure A, from which the long‑term Hydrostatic Design Basis (HDB) and pressure rating of a pipe product are derived.


ASTM D2992 Fiberglass Pipe Hydrostatic Test for Obtaining Hydrostatic or Pressure Design Basis

1. What is ASTM D2992?

ASTM D2992 is an ASTM International Standard Practice (current edition D2992-24) titled “Standard Practice for Obtaining Hydrostatic or Pressure Design Basis for ‘Fiberglass’ (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings.” It describes how to generate, analyse and extrapolate stress-rupture or pressure-rupture data to establish a long-term design basis for GRP pipe, fittings and joints. 


2. Is ASTM D2992 a test method or a pass/fail test?

Neither — it is a practice. It does not produce a pass or fail result, and it does not itself specify the test apparatus. It prescribes how to plan the test programme, distribute failure points, discard invalid data, perform the log-log regression, and categorise the extrapolated value. The actual physical testing is performed by the referenced methods: ASTM D2143 for Procedure A and ASTM D1598 (or F948) for Procedure B. Where D2992 and the underlying method disagree, D2992 governs.


3. What is the difference between HDB, PDB, HDS, HDP and LTHS?

The chain runs in one direction:

  • LTHS / LTHP — Long-Term Hydrostatic Strength / Pressure: the hoop stress or internal pressure extrapolated to cause failure at a specified life.

  • HDB / PDB — Hydrostatic / Pressure Design Basis: the LTHS or LTHP rounded down into an ISO 3 R10 preferred-number category.

  • Service design factor — a number ≤ 1.00 chosen by the design engineer.

  • HDS / HDP — Hydrostatic Design Stress / Pressure = HDB (or PDB) × service design factor.

  • PR — Pressure Rating: the final allowable continuous pressure, derived from HDS via the ISO hoop-stress equation.

In short: test data → LTHS/LTHP → HDB/PDB → × design factor → HDS/HDP → pressure rating.


4. What is the difference between Procedure A and Procedure B?

Procedure A (cyclic) cycles internal pressure at 25 cycles/min (per ASTM D2143) and records cycles to failure; the design life is expressed as 150 × 10⁶ or 657 × 10⁶ cycles. Procedure B (static) holds constant internal pressure (per ASTM D1598 / ISO 1167) and records hours to failure; the design life is 100 000 h or 438 000 h. Both need ≥ 18 failure points per temperature, both fit a log-log regression, and both extrapolate to nominally 50 years. Procedure A usually generates data faster; Procedure B better represents continuously pressurised service.


5. Why is the design life 657 million cycles or 438 000 hours?

Both equal 50 years. 438 000 h = 50 × 8 760 h. 657 × 10⁶ cycles = 50 years at the D2992 cycle rate of 25 cycles/min (50 × 365.25 × 24 × 60 × 25 ≈ 6.57 × 10⁸). The standard also permits the shorter 150 × 10⁶-cycle / 100 000-h intercepts, with the actual target specified by the relevant product standard.


6. How many specimens are required for ASTM D2992?

A minimum of 18 failure points per selected test temperature, for both Procedure A and Procedure B. The points must be deliberately spread over three or more logarithmic decades of time so that the regression is statistically meaningful — not clustered at one time scale. For a Section 12 reconfirmation after a material or process change, the minimum drops to 6 specimens in two sets of ≥ 3.


7. How are the 18 failure points distributed?

Procedure A (cycles): ≥ 3 points each in 1 000–10 000, 10 000–100 000, 100 000–1 000 000 and 1 000 000–10 000 000 cycles, plus ≥ 1 point after 15 000 000 cycles.
Procedure B (hours): ≥ 4 points in 10–1 000 h, ≥ 3 points in 1 000–6 000 h, ≥ 3 points after 6 000 h, plus ≥ 1 point after 10 000 h.


8. What counts as a “failure” in ASTM D2992?

Transmission of the test fluid through the body of the specimen in any manner — a wall fracture, a localised leak, or weeping — at a distance greater than one diameter from the end closure. A leak occurring within one diameter of an end closure is an invalid test item, not a failure, and is not recorded; the specimen may be repaired and testing resumed. This boundary exists so that end-condition artefacts do not contaminate the failure-mode statistics.


9. Can specimens that have not failed be used as data points?

Yes, with conditions. Specimens surviving more than 15 000 000 cycles (Procedure A) or 10 000 h (Procedure B) may be counted as failures when establishing the regression line. This may raise or lower the resulting LTHS/LTHP, but the lower confidence value requirement must still be satisfied. Unfailed specimens may also be left under test and the line recalculated as real failures are obtained.


10. What data points must be excluded from the regression?

Points whose average life at a given level is < 500 cycles (Procedure A) or < 0.3 h (Procedure B). Averages are taken over tests at the same level — a stress within ±200 psi (1 380 kPa) or a pressure within ±20 psi (138 kPa). Excluded points must still be listed in the report and identified as belonging to this category.


11. What is the hoop stress equation used in D2992?

S = P(D − t) / 2t, where S = hoop stress (psi or kPa), P = internal pressure, D = average reinforced outside diameter, and t = minimum reinforced wall thickness. D and t are measured in accordance with ASTM D3567 and exclude veil-reinforced and non-reinforced coatings and linings; for fittings, thickness is taken at the thinnest section of the body.


12. Why use hoop stress instead of pressure?

Hoop stress normalises the data for differences in specimen diameter and wall thickness. That turns pressure — a geometry-dependent quantity — into a material parameter, which reduces scatter and lets a design basis measured on one pipe size be applied to all sizes made with the same materials and process (Section 5.3). The limitation is that hoop stress can only be calculated for simple hollow cylinders. For fittings, joints and complex shapes, the practice switches to the pressure basis (PDB).


13. What is the difference between free-end and restrained-end closures?

Restrained-end closures use a tie rod through the specimen or an external frame to take the pressure end thrust, so the specimen sees hoop and radial stress only — the resulting HDB applies only to hoop-direction stresses. Free-end closures seal the ends so pressure also produces longitudinal stress, with hoop stress twice the longitudinal stress; such data should not be used where service longitudinal stress exceeds 50 % of the HDS. The choice is made to match the stress state and joint type of the intended piping system.


14. What equipment is needed for ASTM D2992 testing?

A pressure generation and control system (cycling at 25 cycles/min for Procedure A; constant-pressure hold within ±1 % for Procedure B); free-end or restrained-end closure tooling; a temperature conditioning system — circulating heated liquid, controlled water bath, or controlled air chamber — holding the test fluid within ±3 °C (5 °F); leak/weeping detection (visual or electronic); calibrated pressure transducers, cycle counters and elapsed-time timers (±2 % or 40 h); dimensional metrology per ASTM D3567; and statistical software implementing the mandatory Annex A1 least-squares analysis.


15. How long does an ASTM D2992 test programme take?

Typically 12 to 18 months for a full Procedure B qualification, because the long-life points must exceed 10 000 h (≈ 14 months). Procedure A is usually faster because 15 000 000 cycles at 25 cycles/min is about 417 days at the upper end but the bulk of the points are far shorter. Running many stations in parallel is the practical way to compress the calendar time — which is why station count is the single most important specification when buying a machine.


16. Does ASTM D2992 give the service design factor?

No — deliberately. ASTM states it will not develop or issue recommended service design factors. The factor (a number ≤ 1.00) is chosen by the design engineer after evaluating manufacturing and testing variables (material variability, manufacture, dimensions, handling, evaluation procedure) and application variables (installation, environment, temperature, hazard, desired life expectancy, required reliability).


17. Can one machine perform both Procedure A and Procedure B?

Yes, if it is specified that way. A combined platform needs a fast-cycling pressure circuit (25 cycles/min) and a high-stability long-term hold circuit (±1 % for months), plus the right closure tooling. Beijing Tnited Test Co., Ltd configures HYD-F with both modes; many labs buy separate cyclic and static machines so neither programme is ever blocked.


18. What pressure and temperature range should I specify?

Specify from your product range, not from the standard — D2992 does not fix a pressure range. Give the supplier your maximum test pressure (remember the ~20 %-of-HDS practical ceiling), pipe OD range, wall-thickness range, joint type, and highest test temperature. Temperature matters: water baths typically top out near 95 °C, so higher-temperature work needs an air chamber or circulated-fluid system.


< Previous: ASTM D2924 External Pressure Resistance Test of Fiberglass Pipe

> Next: ASTM D3029 Impact Resistance of Flat Rigid Plastic By Falling Tup Weight

Require More Customized Solutions?

We offer customization to meet your specific needs. Our expert team will collaborate with you to develop the perfect product for you
Customize Now

Beijing United Test Co., Ltd.