Information on the most widely used ASTM standards within the materials testing industry
HDPE pipe hydrostatic pressure long-term, burst test constant temperature tank
HDPE pipe hydrostatic pressure long-term, burst test constant water tank. The constant temperature water tank is a crucial piece of equipment for
hydrostatic pressure tests, particularly for long-term and burst tests.
It is designed to maintain a constant pressure and temperature during
testing, which is essential for accurately assessing the strength and
durability of pipes under sustained conditions.
Feature of water tank:
1,
Constant-temperature tank is composed of 304# stainless steel interior
and aluminum alloy/steel plate outer plate, no corrosion,
2, Imported circulation pump, high accuracy heater and temperature holding system;
3,
Rigid and thick heat insulation polyurethane foam, and temperature
proof layer to ensure the temperature and energy keeping performance,
avoid energy loss.
4, For big tank, the cover of tank equipped with automatic lifting device, more reliable and convenient;
General introduction
The constant temperature water tank is a crucial piece of equipment for hydrostatic pressure tests, particularly for long-term and burst tests. It is designed to maintain a constant pressure and temperature during testing, which is essential for accurately assessing the strength and durability of pipes under sustained conditions.
Feature of water tank:
1, Constant-temperature tank is composed of 304# stainless steel interior and aluminum alloy/steel plate outer plate, no corrosion,
2, Imported circulation pump, high accuracy heater and temperature holding system;
3, Rigid and thick heat insulation polyurethane foam, and temperature proof layer to ensure the temperature and energy keeping performance, avoid energy loss.
4, For big tank, the cover of tank equipped with automatic lifting device, more reliable and convenient;

Key Features
15℃~ 95℃ (Add cooling device optional)
1, Constant-temperature tank is composed of 304# stainless steel
interior and aluminum alloy/steel plate outer plate, no corrosion,
2, Imported circulation pump, high accuracy heater and temperature holding system;
3,
Rigid and thick heat insulation polyurethane foam, and temperature
proof layer to ensure the temperature and energy keeping performance,
avoid energy loss.
4, For big tank, the cover of tank equipped with automatic lifting device, more reliable and convenient;
Main technical specification
| Working station | 1 to 20 working stations |
| Burst test | All stations can execute the burst test |
| Hydrostatic pressure test | All stations can execute the long-term hydrostatic pressure test |
| Max. pressure | 0 ~ 10Mpa (100 bar) / 0 ~ 20Mpa (200 bar) |
| Constant pressure accuracy | -1%, +2% |
| Pressure resolution | 0.001Mpa |
| Time count range | 1~9999h 59min 59s |
| Time display accuracy | 1s |
| Constant temperature | Ambient temperature to 95℃ 15℃ to Ambient temp. with cooling unit |
| Temp. indication accuracy | ±0.5℃ |
| Power supply | 380V AC 50HZ, 3 phase |
| Pipe sample diameter range | 10-2000mm (Customized) |
| Standard End cap | φ16, φ20, φ25, φ32, φ40, φ50, φ63, φ75, φ110, φ125, φ140, φ160, φ180, φ200, φ225, φ250,φ280, φ315, φ355, φ400, φ450, φ500, φ560, φ630, φ710, φ800, φ900, φ1000, φ1100, φ1200, φ1300… |
| Customized end cap | φ1/2",φ3/4",φ1" …. φ20" etc., inch sizeor any other size according requirement. |
Main accessories
Constant temperature tank (stainless steel interior) | 1 set |
Standard
ISO 7509 Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of time to failure under sustained internal pressure
ISO 7509 specifies a laboratory method for measuring how long a GRP pipe specimen survives under a constant internal hydrostatic pressure at a controlled temperature. It is a long-term, slow-rate stress-rupture test — not a short-term burst test.
ASTM D2992 Practice for Obtaining Hydrostatic or Pressure Design Basis for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings
ASTM D2992 is not a "pass/fail" test — it is a statistical extrapolation practice. It defines how to take short-term pressure-rupture data on fiberglass (GRP) pipe and fittings, fit a log-log regression line, and extrapolate it to a 50-year design life in order to publish a Hydrostatic Design Basis (HDB) or Pressure Design Basis (PDB) for that specific product and manufacturing process.
ASTM D1598 Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure. It is a fundamental test method used to determine the long-term hydrostatic strength and resistance of thermoplastic pipe by applying a constant internal pressure until the pipe specimen fails (ruptures). Which is critical for establishing hydrostatic design basis and ensuring long-term pipeline reliability.
ISO 9080 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation.
ISO 9080 specifies a statistical extrapolation method (Standard Extrapolation Method, SEM) to predict long‑term hydrostatic performance of thermoplastic pipe materials, instead of conducting multi‑decade real‑time ageing tests.
ISO 1167: 2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids -- Determination of the resistance to internal pressure.
ISO 1167 test method specifies a general test method for determining the resistance to internal hydrostatic pressure at a given temperature of thermoplastics pipes, fittings and piping systems for the transport of fluids. The method accommodates water-in-water, water-in-air and water-in-liquid tests. It defines uniform hydrostatic pressure testing to evaluate short-term and long-term pressure-bearing durability of thermoplastic fluid-transport piping systems.
Hydrostatic pressure testing is a valuable method for assessing the strength and integrity of pressurized systems, ensuring that they can meet operational demands without failure. Hydrostatic pressure testing can evaluate these items by filling pipelines, tanks, or containers with water before pressure is applied to detect any potential leaks or issues.
Hydrostatic pressure tester is critical across multiple industries, from pipeline engineering to industrial piping. It helps prevent costly failures or leaks by verifying whether the system can safely reach the specified pressure levels.
ASTM D1598: Standard Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure.
ASTM D1598 test method covers the determination of the time-to-failure of both thermoplastic and reinforced thermosetting/resin pipe under constant internal pressure.This test method provides a method of characterizing plastics in the form of pipe under the conditions prescribed.
ASTM D1599: Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings.
ASTM D1599 test method establishes the short-time hydraulic failure pressure of thermoplastic or reinforced thermosetting resin pipe, tubing, or fittings. Data obtained by this test method are of use only in predicting the behavior of pipe, tubing, and fittings under conditions of temperature, time, method of loading, and hoop stress similar to those used in the actual test. They are generally not indicative of the long-term strength of thermoplastic or reinforced thermosetting resin pipe, tubing, and fittings
ASTM D1599 is titled "Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings." It is a fundamental short-term, destructive pressure test used to determine the ultimate failure pressure (often called the "burst pressure") of thermoplastic pipe, tubing, or fittings under rapidly applied internal pressure at a specified temperature. Typically completed within 60–70 seconds, mainly for quality control and short-term design validation.
Require More Customized Solutions?