Home >> Application >> By Standard >> ISO >> ISO 10000~19999 >> ISO 12405-3 Battery Safety Test Equipment & Test Methods

ISO 12405-3 Battery Safety Test Equipment & Test Methods

Share:

ISO 12405-3 EV Lithium-ion Traction Battery Safety Test Machine | UnitedTest

UnitedTest manufactures ISO 12405-3 battery safety testing equipment for Class-B lithium-ion traction battery packs and systems of electric road vehicles. Our test rigs execute mechanical, climatic, crash simulation, electrical fault and thermal failure tests to assess risks including electrolyte leakage, rupture, fire, explosion and insulation breakdown, supporting automotive battery R&D, quality validation and compliance certification. This standard focuses on in-vehicle operational safety rather than transportation, storage or maintenance safety.


ISO 12405-3 sets out standardized safety performance test protocols and acceptance criteria for Voltage Class‑B lithium‑ion traction battery packs and battery systems fitted to electrically propelled road vehicles, excluding two‑wheel and three‑wheel electric vehicles. The testing suite covers multiple hazardous scenarios, exposing battery assemblies to mechanical abuse, extreme climatic conditions, crash impact simulation, electrical malfunction and thermal control failure. Testers evaluate critical failure modes such as electrolyte leakage, structural rupture, thermal runaway, fire, explosion and high‑voltage isolation failure. It serves automotive battery engineers, test laboratories and battery manufacturers to verify in‑vehicle service safety, validate design robustness, compare different cell and pack architectures, and meet third‑party certification requirements. UnitedTest supplies fully integrated ISO 12405‑3 compliant battery safety test machines, helping customers carry out repeatable, traceable abuse testing for new energy vehicle traction batteries.


ISO 12405-3 test item → UnitedTest equipment mapping

Test methodTest Standard relatedTypical Testing Equipment
Pre-conditioning cyclesISO 12405-1 / -2HV battery cycler
Vibration (fatigue)ISO 12405-1 / -2Three-axis vibration test system / battery shaker
Mechanical shock12405-1 / -2Mechanical shock / bump test machine
Dewing (temperature change)ISO 12405-1 / -2Humidity climatic chamber
Thermal shock cyclingISO 12405-1 / -2Two-/three-zone thermal shock chamber
Inertial load at vehicle crashFully specifiedCrash simulation sled / pulse-shaping rig
Contact force at vehicle crash (crush)Fully specified100 kN battery pack crush test machine
Water immersionNo procedure; routed to short circuitNo immersion tank required
Exposure to fireFully specified + Annex B screenFuel-pan fire exposure test rig
Short circuitISO 12405-1 / -2Short-circuit test bench + cycler
Overcharge / overdischarge protectionISO 12405-1 / -2HV battery cycler + thermal chamber
Loss of thermal control/coolingFully specifiedConvective oven / climatic chamber with HV feedthroughs


Details instroduction of the ISO 12405-3 Battery Safety Test Equipment & Test Methods

1, Mechanical strength & fatigue tests
1.1 Vibration— fatigue / durability

Verify safety performance under the mechanical vibration load a battery system will likely experience during normal vehicle operation.

This is the classic fatigue item: cumulative damage to welds, busbars, fasteners, cell interconnects, seals and coolant joints.

According: ISO 12405‑1, ISO 12405‑2, UN ECE R100‑02.

Test Equipment

Electrodynamic vibration shaker system; fixture replicating vehicle mounting; liquid‑cooled DUT needs coolant supply / port‑sealing accessories; 

Temperature monitoring sensors.

Test Specimen info

Complete battery pack / battery system; representative battery‑pack subsystem is permitted.

SOC setting per customer‑supplier agreement (≥ 50 % SOC for high‑power; max normal‑operation SOC for high‑energy).

Mandatory Stipulations

Option 1: follow vibration profile defined in ISO 12405‑1 (high‑power battery) or ISO 12405‑2 (high‑energy battery).

Option 2: customer‑defined vehicle‑specific vibration profile (UN ECE R100‑02 gives reference profile).

Liquid‑cooled DUT must be filled with specified coolant; cooling ports either connect to external cooling loop or sealed to retain internal coolant. 

Room temperature (RT = 25 ± 2 °C) as default test temperature.

1.2 Mechanical Shock Test Validate safety under shock loads from normal driving: hard braking, hitting potholes / road bumps. Excludes vehicle‑crash shock scenarios.
Test EquipmentMechanical shock test bench / shock impact tester; vehicle‑simulation mounting fixture; multi‑channel temperature & voltage monitoring system.
Requirement

Specimen: Battery pack / battery system / qualified subsystem. Pre‑condition cycles required. SOC agreed between supplier‑customer.

Test procedure: Secure DUT using vehicle mounting fixture, apply selected shock pulses. Post‑test visual check and isolation resistance measurement.

1.3, Inertial Load at Vehicle Crash

Assess DUT safety under high‑acceleration inertial pulse loads generated in real vehicle crash events. 

This test can be omitted if full‑vehicle crash test (Option b) is performed.

(simulated crash inertia shock, accident‑simulated mechanical breaking‑damage test)

Test Equipment

Test equipment: High‑force acceleration pulse test rig / crash‑inertia test bench; vehicle‑duplicate mounting fixtures;

 multi‑channel high‑speed data logger (acceleration, voltage, temperature); coolant handling set for liquid‑cooled DUT.

Test eequirement

Specimen: DUT battery pack / system with full original mounting interfaces. Liquid‑cooled DUT filled with production‑spec coolant. 

Test procedure (Option a: component‑level bench test):

    1. Fix DUT with real‑vehicle attachment fixture on test rig.

    2. Apply crash inertial acceleration pulse following corresponding vehicle‑mass pulse corridor.

    3. After pulse, keep 1‑hour post‑test observation period, visual inspection and isolation resistance measurement.

1.4 Contact Force at Vehicle Crash

Crush / Compression damage test. Evaluate safety performance under contact crush force induced in vehicle crash (battery extrusion / compression damage simulation).

Can be omitted if full‑vehicle crash test (8.1 option b) is performed.

Test requirement

Hydraulic compression / crush test machine; two crush probes:① crush‑plate (Figure 3: max 600 × 600 mm, R75 ribs);

② 150 mm‑diameter half‑cylinder indenter (each end extends ≥ 50 mm beyond DUT edge); 

dedicated mounting fixture; high‑speed force‑displacement data acquisition system; coolant containment setup for liquid‑cooled battery.


2, Climatic Aging / Environmental Tests
2.1 Dewing (Temperature‑change test)

Simulate dew‑condensation climatic loads occurring over vehicle service lifetime.

Test equipment: Temperature‑change climatic test chamber.

Related standards: ISO 12405‑1, ISO 12405‑2.

2.2 Thermal‑shock cycling test

Verify DUT resistance to sharp ambient‑temperature swings during vehicle service life.

Test equipment: Thermal‑shock test chamber (two‑zone hot‑cold shock chamber). Liquid‑cooled DUT retains coolant inside but cooling system function disabled during cycling.

Related standards: ISO 12405‑1, ISO 12405‑2.

3. Simulated‑vehicle‑accident additional tests
3.1 Water Immersion

Purpose: Simulate vehicle‑flooding water immersion scenario. Notes immersion may induce short‑circuit risk (cross‑reference short‑circuit electrical test). 

No detailed immersion procedure defined in ISO 12405‑3 itself.

Equipment suggestion: Water‑immersion tank (fresh‑water / salt‑water optional).

3.2 Exposure to fire test

Simulate external under‑vehicle fuel fire (spilled‑fuel fire), provide passenger evacuation time margin. Test exempted if DUT casing lowest surface > 1.5 m above ground.

Test equipment: Fire‑test pan with liquid‑fuel supply; steel grating test table; refractory fire‑brick screen 

(Annex B defines screen geometry & material: SK30 Seger‑cone, Al₂O₃ 30‑33 %, open porosity 20‑22 %); 

high‑temperature thermal‑monitoring system; wind‑shield enclosure (wind speed ≤ 2.5 km/h at pan level).

Test phases:

    • Phase A pre‑heating (optional if fuel temp ≥ 20 °C): fuel ignited remotely, pre‑burn 60 s then move pan under DUT.

    • Phase B direct flame exposure: 70 s direct fuel‑fire burning under DUT.

    • Phase C indirect flame exposure: install refractory screen, additional 60 s reduced‑radiation exposure; alternatively extend Phase B another 60 s by customer‑supplier agreement.

4. Other test

Short‑circuit test: Validate over‑current‑protection device can cut short‑circuit current

Over‑charge protection test: Verify over‑charge protection cuts over‑charge current

Over‑discharge protection test: Verify over‑discharge protection cuts over‑discharge current

Loss of thermal‑control / cooling test: Verify DUT prevents internal overheating when cooling / thermal control fails


Keywords: ISO 12405-3 battery tester, EV traction battery safety test machine, lithium-ion battery pack abuse test, electric vehicle battery crash simulation test, thermal runaway test rig, high voltage battery insulation test, automotive battery mechanical test, climatic battery safety test, battery leakage fire explosion test, rechargeable energy storage system test, new energy vehicle battery test equipment, battery compliance test bench, UnitedTest battery testing system, EV lithium battery safety validation, traction battery abuse testing equipment

Related products and device

Hydraulic fatigue dynamic testing machine

Hydraulic fatigue dynamic testing machine mainly used at a variety of material and components, parts for both dynamic and static mechanical property testing, include tension, compression, low cycling test, match with high-low temperature chamber can execute the temperature test.

IK Protection Degree Impact Testing Machine (IK Vertical Impact Tester)

UnitedTest manufactures IK vertical impact testing machine complying with IEC 62262, IEC 60068-2-75 Test Ehc vertical hammer. For IK rating test, IK01-IK10 enclosure mechanical impact resistance test, with standard fixtures, calibration, lab & certification testing. Get IK vertical drop hammer impact tester details.

tensile testing machine

A single column tensile tester is a sophisticated material testing instrument designed for measuring mechanical properties of various materials under tension, compression, bending, shear, and other loading conditions. As the name suggests, it features a single vertical column supporting a moving crosshead that applies force to test specimens.

Related Standard

EN 477 Falling Mass Impact Test for PVC Profiles –

EN 477 Plastics‑Poly(vinyl chloride) (PVC)‑based profiles‑Determination of the resistance to impact of profiles by falling mass

EN 477 specifies a drop‑weight impact test for rigid unplasticized PVC‑U profiles, primarily performed at −10 °C, and can also apply for other defined test temperatures for PVC‑based profiles.


ASTM D3029 Impact Resistance of Flat Rigid Plastic By Falling Tup Weight –

ASTMD3029 is designed to determine the relative ranking of rigid plastic materials based on the energy required to crack or break them under specified impact conditions.

ASTM D5420 Gardner falling weight impact test for flat rigid plastic –

ASTMD5420 measures the relative ranking of materials based on the energy required to crack or break a plastic sheet when struck by a falling weight (the "Gardner Impact" method).



ASTM D5628 Falling Tup Impact Resistance Test of Rigid Plastics –

ASTMD5628 specifies a falling‑dart/tup method to measure the threshold impact‑failure energy for flat rigid plastics. It uses the Bruceton Staircase (Up‑and‑Down) Method to determine the energy causing 50% of specimens to fail (mean‑failure energy, MFE).

ISO 6603-1 Rigid plastics falling dart puncture-impact test –

ISO 6603-1 specifies falling-dart methods to measure the puncture‑impact performance of rigid plastics using only the 50% impact‑failure energy (E₅₀) threshold, without recording force–time or force–deflection curves.

ISO 11173 Plastic pipe falling weight impact test –

ISO 11173 specifies the staircase falling-weight impact method to evaluate the external impact resistance of circular thermoplastic pipes, mainly for batch qualification at 0 °C (–20 °C recommended for sub-zero testing).

EN 744 for falling weight impact testing of thermoplastics pipes –

EN 744 specifying the round-the-clock falling-weight impact method to evaluate the resistance to external blows of circular cross-section thermoplastics pipes. It's a standardized procedure to determine the ability of thermoplastic pipes to withstand external impacts without failing.


FAQ: ISO 12405-3 Battery Safety Test Equipment & Test Methods

1. What is ISO 12405-3:2014 and what is it used for?

ISO 12405-3:2014, first edition published 2014-05-15 by ISO/TC 22/SC 21, specifies test procedures and acceptable safety requirements for voltage class B lithium-ion traction battery packs and systems used in electrically propelled road vehicles. It is a safety performance standard, not an electrical-performance or cycle-life standard: the question it answers is whether the DUT stays safe under mechanical, climatic, crash, fire and electrical abuse. Two- and three-wheel vehicles are excluded, as are transport, storage, vehicle production, repair and maintenance services.


2. What is a DUT under ISO 12405-3, and which specimens are allowed?

The DUT (device under test) is a battery pack, a battery system, or a representative battery pack subsystem. A pack contains cells or cell assemblies, the voltage class B circuit, an overcurrent shut-off device and electrical, cooling and communication interfaces; a system adds the BCU, contactors and control electronics. A subsystem must include all customer-specified parts, including mechanical and electrical connecting points. The supplier must deliver operating documentation, connectors and plugs including cooling, and a BCU with test modes and bus communication. DUT status (new, previously tested or used) and its history must be agreed and documented before testing.


3. What test equipment is required for ISO 12405-3 compliance?

A complete ISO 12405-3 test equipment list includes a three-axis vibration test system with sine and random control, a mechanical shock tester, a humidity chamber for dewing, a thermal shock chamber, a crash simulation sled capable of trapezoidal acceleration pulses, a servo-hydraulic battery pack crush test machine rated at least 100 kN, a fuel-pan fire exposure test rig with grating table and Annex B refractory screen, an HV battery cycler, a short-circuit rig and a convective oven with HV feedthroughs. Add multi-channel DAQ, an insulation resistance tester for ISO 6469-1 measurements, and a one-hour observation bay with blast and fume protection.


4. Does ISO 12405-3 fix vibration parameters, and what shaker should I buy?

No. Clause 6.1.2 offers two options: a profile per 8.3.2.1 of ISO 12405-1:2011 (high-power, typically HEV/FCV) or ISO 12405-2:2012 (high-energy, typically BEV), or a customer-defined vehicle-specific vibration profile. A profile is also given in UN ECE R100-02. Liquid- or refrigerant-cooled DUTs must be filled with coolant, with the external cooling circuit maintained or the ports sealed, and a battery pack subsystem may be used. For how to choose a battery pack vibration shaker for ISO 12405-3, prioritise arbitrary profile import, three-axis operation, full-pack payload, long continuous duty, coolant and BCU integration, and DAQ meeting ±0.5 % V/I and ±1 K. The Chinese equivalent GB/T 31467.3-2015 originally used 21 h per axis random vibration (Z → Y → X) before its 2017 amendment adopted a 3 h R100-style sine sweep — a good reason not to hard-code one curve.


5. What is the difference between mechanical shock and inertial load at vehicle crash?

Mechanical shock covers normal driving events — sudden braking deceleration, potholes and road bumps — and the standard explicitly says it does not include a vehicle crash. Inertial load at vehicle crash reproduces crash deceleration using a trapezoidal time–acceleration corridor (Figure 1, 0–120 ms) between minimum and maximum curves, at (20 ± 10) °C, with contactors closed and relevant control units operational. They belong to different machine classes: a shock/bump test machine versus a crash simulation sled. If the DUT orientation or load direction is unknown, the DUT must be tested in all six spatial directions.


6. What force and tooling does the ISO 12405-3 crush test require?

The ISO 12405-3 crush test force requirement is (100 −0/+5) kN, or a customer value justified by crash tests or crash simulations; ramp-up must be under 3 min and hold time between 100 ms and 10 s, at (20 ± 10) °C. Tooling is either a 600 mm × 600 mm or smaller crush plate with R15 ribs at 30 mm spacing, or a 150 mm diameter half-cylinder extending at least 50 mm beyond both DUT edges, centred on the geometric centre of the projected plane. For vehicles over 3.5 t the test applies only if the RESS bottom is below 700 mm from the ground; it does not apply inside a longitudinal chassis frame in vehicles over 7.5 t. Acceptance is no rupture, fire or explosion during the test plus a 1 h observation — note that leakage is not listed in 8.2.3. A 100 kN battery crush test machine with closed-loop force control and calibration headroom is the right specification.


7. What equipment is needed for the ISO 12405-3 exposure to fire test?

Key ISO 12405-3 fire exposure test pan and screen dimensions: the pan must exceed the DUT horizontal projection by 200–500 mm, with sidewalls no more than 80 mm above the initial fuel level; the fuel level to DUT bottom equals the design ride height, or approximately 500 mm if unspecified; either pan or fixture must move freely horizontally. The grating table uses 6–10 mm steel rods spaced 40–60 mm. The Annex B refractory screen is placed (30 ± 10) mm above the fuel, with SK30 fire resistance, 30–33 % Al2O3, 20–22 % open porosity, 1900–2000 kg/m3 density, ∅30 mm holes on 37 ± 3 mm pitch, 44.18 % effective holed area, and a 10–20 mm ventilation gap to the pan wall. Phases: A = 60 s pre-heating at ≥3 m (omitted if fuel ≥20 °C), B = 70 s direct flame, C = 60 s indirect flame through the screen, or extend B by 60 s by agreement. Ambient ≥0 °C, wind ≤2.5 km/h. Only the pan is extinguished afterwards; the DUT is observed until ambient or decreasing for at least 3 h. The sole acceptance criterion is no explosion, and the test is not required when the lowest DUT casing surface is over 1.5 m above ground.


8. Which chamber do I need for dewing and thermal shock cycling?

Clause 7.1 dewing uses a temperature/humidity climatic chamber, with the procedure taken entirely from 8.1.2 of ISO 12405-1:2011 or ISO 12405-2:2012 — Part 3 gives no numeric humidity values. Clause 7.2 uses a two- or three-zone thermal shock chamber for battery packs: cycles start at ambient temperature, then high/low cycling per 8.2.2 of Parts 1 or 2. Part 3's note offers maximum ambient (60 ± 2) °C and 6 h dwell at temperature extremes. Liquid-cooled DUTs keep coolant present but all thermal control must be non-operational. Size the chamber for full-pack volume, long dwells, HV/BCU feedthroughs and continuous temperature logging.


9. Does ISO 12405-3 require a water immersion tank?

No. Clause 8.3 contains no immersion procedure and no parameters. It states that the lithium-ion-specific worst case of immersion in clear or salty water is an external short circuit, and routes the evaluation to the short-circuit test in 9.1; it also notes possible hazardous gas release and loss of electrical isolation. Immersion tanks are needed for the seawater immersion tests in GB/T 31467.3-2015 and GB 38031, not for ISO 12405-3:2014 compliance. Do not let a supplier sell you an "ISO 12405-3 immersion tank" without checking the clause.

< Previous: ISO 12236 Static Puncture Test (CBR test) for Geosynthetics

> Next: ISO 12417-1 Test Methods for Cardiovascular implants and extracorporeal systems

Require More Customized Solutions?

We offer customization to meet your specific needs. Our expert team will collaborate with you to develop the perfect product for you
Customize Now

Beijing United Test Co., Ltd.