Information on the most widely used ASTM standards within the materials testing industry
ASTM D5025 Standard Laboratory Burner for Plastic Small-Scale Burning Tests | UnitedTest
UnitedTest supplies ASTM D5025 compliant standard laboratory burners, the certified ignition source for plastic flammability tests. Compatible with methane, propane and butane, adjustable flame height from 20 mm to 125 mm for polymer fire testing and certification.
ASTM D5025 specifies the dimensional and performance requirements for the standard laboratory burner used as the ignition source in small-scale burning tests of plastic materials. This standard burner works with methane, propane or butane fuel gas and supports adjustable flame heights ranging from 20 mm to 125 mm for vertical and horizontal flammability assessments. It is noted that fire testing carries inherent hazards, so proper protective measures must be implemented to safeguard operators and laboratory assets. UnitedTest manufactures calibrated ASTM D5025 burners integrated into plastic flammability test systems for material R&D, quality inspection and regulatory compliance.
Test principle
This burner works on premixed gas‑air combustion principle. Fuel gas (methane, propane or butane) jets through the precision orifice, entrains ambient air through side air‑inlet slots inside the mixing tube, forms premixed fuel‑air mixture, then burns at the top outlet to produce stable calibrated test flames (20 mm / 50‑W or 125 mm / 500‑W flame). The needle‑valve adjusts gas flow rate; rotating the barrel changes the opening degree of air‑inlet slots to tune air intake for stable flame morphology. This standardized ignition source delivers repeatable thermal input for plastic flammability assessment.
Test equipment required for ASTM D3801 Horizontal & Vertical Flame Test
Recommend UntiedTest UL94 Horizontal & Vertical Flame Tester,
The burner is assembled from metal (brass or aluminum preferred), including a threaded burner barrel, one‑piece base, gas orifice, needle‑valve assembly, gas inlet fitting, and optional lock nut, consist of below:
| Burner barrel (mixing tube) | seamless tube; inner diameter 9.5 ±0.3 mm. Length from air‑inlet openings top to tube outlet: 100 ±10 mm. No stabilizer or end attachments on tube top. Minimum total air‑inlet opening area: 225 mm², equally distributed around the adapter (typically three slots). |
| Orifice | Diameter 0.90 ±0.03 mm, length 1.60 ±0.05 mm, machined on the burner base. |
| Needle valve | 40° conical needle tip; maximum flat top of tip ≤0.4 mm. Knurled knob for manual gas‑flow adjustment. Needle must keep precise co‑axial alignment with the orifice, to guarantee vertical flame output. |
| Gas inlet | serrated hose fitting for connecting fuel‑gas supply. |
| Optional lock nut | secures barrel position when air‑inlet slots are partially or fully opened. |
Key Test Parameters
| Flame heights | 20 mm (≈50 W) and 125 mm (≈500 W) — the standard covers 20–125 mm |
| Fuel gases | Methane, propane, or butane |
| Mixing tube bore | 9.5 ± 0.3 mm |
| Barrel length | 100 ± 10 mm |
| Orifice | Ø 0.90 ± 0.03 mm × 1.60 ± 0.05 mm long |
| Needle cone angle | 40°, flat top ≤ 0.4 mm |
| Air-inlet area | ≥ 225 mm² (equidistant) |
| Adapter size | ~25 mm H × 20 mm OD |
| Calibration practice | D5207 |
Procedure of ASTM D5025 Small-scale burning tests on plastic materials
ASTM D5025‑20 does not provide material‑burning test‑step procedures. It only defines burner‑related operation and verification steps:
Assemble burner components following drawing requirements, install lock nut as needed.
Connect fuel‑gas supply to serrated inlet fitting.
Remove burner barrel, open gas supply and ignite gas directly at orifice to check vertical‑flame alignment; repair if flame tilts.
Re‑install barrel; adjust barrel rotation position to set air‑inlet opening area; adjust needle‑valve knob to regulate gas flow.
Perform flame calibration and confirmation according to ASTM D5207 to achieve target 20 mm or 125 mm flame height.
The calibrated burner is then used as ignition source, following full test‑operation sequences from respective test‑method standards (e.g. D635, D3801) for plastic‑sample burning exposure
Industry Application Fields
The burner — and therefore the standards that depend on it — is used wherever small-scale flammability screening of plastics is required:
Electrical & electronics (enclosures, connectors, insulating sheet/tubing, wire coatings) — the dominant field, via UL 94-type tests
Wire & cable and electrical insulation (D229, D876)
Appliances and consumer products (IEC 60695 linkage)
Building and construction products — foams, gaskets, seals (C509, D3014, D4986)
Automotive and transportation interiors (component-level flammability screening)
Foamed/cellular plastics (D3014, D4986)
Plastics resin producers and compounders — formulation development, flame-retardant package optimization, quality control and certification
Related Test Standard:
| IEC 60695‑11‑10 | 50 W horizontal & vertical flame test methods |
| UL 94 | Widely‑used North‑American standard for plastic flammability (HB horizontal burn; V‑0/V‑1/V‑2 vertical burn). Its test setup and evaluation criteria are highly analogous to ISO 1210 / IEC 60695‑11‑10. |
| ASTM D635 | US horizontal‑burning rate test for plastics (similar to ISO 1210 Method A). |
| ISO 1210 | Plastics; determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source |
| IEC 60695‑11‑20 | 500 W flame (5V classifications), the "bigger flame" counterpart. |
| ISO 9773 | vertical burning of thin flexible films/sheets (for materials that shrink away, which ISO 1210 cannot handle). |
| ISO 9772 | cellular plastics, horizontal small‑flame burning. |
| ASTM D3801 | vertical, 20 mm flame |
| ASTM D5048 | Higher severity / burn‑through; 125 mm, 500 W flame; 5VA/5VB |
| ASTM D4804 | thin flexible |
| GB/T 2408 (China), AS/NZS 60695.11.10, JIS C 60695‑11‑10, UNE‑EN 60695‑11‑10 — national adoptions of IEC 60695‑11‑10. | |
Keywords: ASTM D5025 laboratory burner, plastic flammability test burner, standard ignition source for burning test, ASTM D5025 flame burner, 20mm-125mm adjustable flame burner, methane propane butane test burner, vertical burning test ignition burner, polymer fire test accessory, UL94 test burner, ASTM D3801 test burner, UnitedTest ASTM D5025 burner, small-scale combustion test burner
Related products and device
Related Standard
ISO 4589-3 — Plastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test.
ISO 4589-3 defines two core output parameters: Temperature Index (TI) — the minimum oxygen volume fraction sustaining flaming combustion at an elevated test temperature; and Flammability Temperature (FT, Annex A normative method) — the temperature at which a specimen just burns in normal air (20.9 % oxygen).
it takes the classic oxygen-index (OI) test and runs it hot, to answer "how flammable is this plastic when it is already hot?"
ASTM D2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)
ASTM D2863 measures the Oxygen Index (OI), also called the Limiting Oxygen Index (LOI):
Oxygen Index (OI) — the minimum concentration of oxygen, expressed as volume percent, in a mixture of oxygen and nitrogen that will just support flaming combustion of a material initially at 23 ± 2 °C under the conditions of this test method.
In plain terms: it answers the question "How much oxygen does this plastic need in the air around it to keep burning like a candle?"
Key interpretive benchmark: Ambient air contains ~21 % oxygen. Therefore:
OI ≤ 21 % → the material will continue to burn in normal air
OI > 21 % → the material is self-extinguishing in normal air (higher = more flame retardant)
ISO 9773 Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small flame ignition source
ISO 9773 specifies a small‑scale laboratory screening method to evaluate relative burning performance of thin, flexible vertically‑oriented plastic specimens exposed to a low‑energy small‑flame ignition source. These thin flexible samples distort or shrink away from flame in IEC 60695‑11‑10 Method B and cannot be evaluated by that vertical‑burn procedureISO. The test measures afterflame time and afterglow time.
ISO 1210 Plastics: determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source
ISO 1210 evaluating the relative burning behaviour of plastic bar specimens exposed to a small‑flame ignition source. It defines two independent test methods: Method A (horizontal burning test) and Method B (vertical burning test). It measures after‑flame time, after‑glow time, damaged length and linear burning rate for comparison of plastic flammability performance.
IEC 60695-11-10 Fire hazard testing - Part 11-10: Test flames; 50 W horizontal and vertical flame test methods
IEC 60695-11-10 define small‑scale laboratory procedures to compare the burning behaviour of materials used in electrotechnical products, using bar specimens exposed to a 50 W nominal small flame ignition source. It determines either the linear burning rate (Method A) or the self‑extinguishing properties (Method B). Applicable to solid and cellular materials with apparent density > 250 kg/m³ (ISO 845).
ASTM D635 Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
ASTM D635 is a small‑scale laboratory screening procedure for comparing the relative linear rate of burning, or the extent and time of burning (or both), of plastics in bar form — molded or cut from sheets, plates, or panels — tested horizontally. It is a fire‑test‑response method: it measures and describes response to heat and flame under controlled conditions, and it explicitly does not by itself constitute a fire hazard or fire risk assessment.
ASTM D4804 Standard Test Method for Determining the Flammability Characteristics of Nonrigid Solid Plastics
ASTM D4804 is a small‑scale vertical‑burning laboratory test designed for thin, flexible non‑rigid solid plastics that deform, shrink or burn up to clamps when tested by ASTM D3801 (rigid plastic vertical burning). It provides optional VTM‑0/VTM‑1/VTM‑2 classification for flexible thin plastics, and is not intended for building construction or finishing plastics.
ASTM D3801 — Standard Test Method for Measuring the Comparative Burning Characteristics of Solid Plastics in a Vertical Position
ASTM D3801 measuring the comparative burning characteristics of solid plastics under vertical‑position small‑scale laboratory conditions. It uses a 20‑mm (50 W) premixed flame to ignite the bottom of vertically clamped plastic specimens, and generates flammability classification results for polymeric materials.
Require More Customized Solutions?