Home >> Application >> By Standard >> ASTM >> ASTM D >> ASTM D3801 Horizontal & Vertical Flame Test

ASTM D3801 Horizontal & Vertical Flame Test

Share:

ASTM D3801 Vertical Burning Tester for Solid Plastics Flammability Test | UnitedTest

UnitedTest manufactures ASTM D3801 vertical burning testing machines to evaluate comparative burning characteristics of solid plastics. This vertical flammability test uses a 50W premixed flame for polymeric material fire classification and lab quality control.


ASTM D3801 is a widely used small-scale vertical burning laboratory test standard for solid plastics. It evaluates comparative burning performance by exposing the bottom of vertically clamped plastic specimens to a 50 W (20 mm) premixed flame, producing flammability classification data for polymeric materials. UnitedTest supplies precision ASTM D3801 vertical flame test equipment for plastic material R&D, quality inspection and regulatory flammability assessment.


Test principle

Under strictly controlled laboratory conditions, pre‑conditioned solid plastic specimens are vertically mounted. A standardized 20‑mm 50 W premixed flame is applied twice to the specimen base. The test records afterflame time, afterglow time, burning‑drip behaviour, and whether drips ignite absorbent cotton underneath. By comparing these combustion responses, materials can be ranked and classified for vertical flammability performance. The test only evaluates material behaviour under this specific lab exposure; it cannot fully replicate real‑world full‑scale fire hazards.

ASTM D3801 Horizontal


Test Specimen Information

Geometry13.0 ± 0.5 mm × 125 ± 5 mm bar
ThicknessSupplied at the minimum and maximum thickness relevant to the end use; materials thicker than 13 mm shall not be tested
Surface qualitySmooth and unbroken; corner radius ≤ 1.3 mm; edges fine‑sanded after cutting to remove burrs, saw marks and filaments
QuantityTwo sets of five specimens (Set A + Set B); labs typically request ~20–22 bars to cover possible retests
Thin materialsFilms/sheet below typical bar thickness fall to D4804 (VTM method) rather than D3801


Test equipment required for ASTM D3801 Horizontal & Vertical Flame Test

Recommend UntiedTest UL94 Horizontal & Vertical Flame Tester, consist of below:

Test chamber / hood

Minimum internal volume of 0.5 m³; no forced or induced air draft during testing; inner surfaces dark‑coloured; light level below 20 lx at specimen position; 

exhaust fan must be switched off during testing, activated after test to remove toxic combustion fumes. 

A closing damper is required if hood creates unintended airflow; optional rear‑view mirror for specimen observation.

ISO 1210 Plastics Horizontal-Vertical Flammability Burning Test

Laboratory burnerComplies with ASTM D5025 specification for plastic small‑scale burning tests.
Ring stand with adjustable clampTo hold specimens firmly in vertical orientation.
Timing deviceAccuracy of ±0.5 seconds, to record afterflame, afterglow and flame‑impingement durations.
Gas supply

Technical‑grade methane (≥98 % purity) as referee gas; natural gas (37 ± 1 MJ/m³ at 25 °C) is acceptable for routine testing; 

equipped with pressure regulator and flow meter for stable gas delivery


Key Test Parameters

FlameBlue premixed methane‑air flame, 20 ± 2 mm high (adjust to yellow‑tipped 20 mm, then increase air until the yellow tip just disappears)
Flame impingement time10.0 ± 0.5 s, applied twice
Burner positionFlame centre at the bottom edge; top of burner 10 ± 1 mm below the specimen
Specimen clampFrom the upper 6 mm; longitudinal axis vertical
Cotton distance300 ± 10 mm below the lower end of the specimen
Burner withdrawal during timing≈ 150 mm (found suitable)
Dripping caseBurner may be tilted up to 45° toward the wide side of the specimen and offset, to avoid molten material entering the burner tube
Timing resolution0.5 s
Sets5 specimens × 2 conditioning sets


Test procedure of ASTM D3801 Horizontal & Vertical Flame Test

  1. Pre‑condition specimens according to standard conditioning requirements to stabilise moisture and volatiles.

  2. Set‑up the enclosed test chamber, turn off exhaust fan; prepare burner, gas supply, timing instrument and cotton indicator underneath the specimen mounting position.

  3. Adjust burner to produce a standard 20‑mm premixed flame.

  4. Mount one pre‑conditioned specimen vertically in the adjustable clamp.

  5. Apply the standard flame to the specimen base for 10 seconds (first flame‑impingement). Remove flame and record the first afterflame time.

  6. Immediately apply the flame for a second 10‑second period right after the specimen stops flaming (or immediately if no flaming occurred). Remove flame and record the second afterflame time and afterglow time.

  7. Observe and document whether flaming drips fall from the specimen and whether those drips ignite the cotton indicator. Record whether burning reaches the holding clamp.

  8. Repeat the full procedure for every specimen in the test set. Compile all timing and drip‑ignition data for the specimen group.

  9. Activate exhaust fan to clear combustion products after finishing each test run.

  10. Evaluate recorded data against classification criteria in the standard appendix to assign V‑0, V‑1 or V‑2 rating; retest a second specimen set if borderline or single‑sample failure conditions are met.


Industry Application Fields

D3801 is the qualification gate for polymeric parts in devices and appliances:

  • Electrical & electronics — connectors, sockets, terminal blocks, switchgear, coil bobbins, relay and contactor housings, enclosures for IT/AV and telecom equipment, PCB‑adjacent parts

  • Household and commercial appliances — housings and internal parts where a small electrical fault or overheated component is the credible ignition source

  • Automotive & transport — interior trim and under‑hood polymer parts requiring a self‑extinguishing rating

  • Lighting, power tools, battery packs and chargers — plastic parts near energy sources

  • Materials supply chain — resin producers use it for flame‑retardant formulation development and batch QC; OEMs for material pre‑selection and incoming inspection; certification bodies as the basis for the UL 94 V rating on yellow cards

It is explicitly not for building construction, wall/floor coverings or furnishings, and it does not address hourly fire resistance, flame spread, smoke or heat release — other tests are required for those end uses.


Related Test Standard:

IEC 60695‑11‑1050 W horizontal & vertical flame test methods
UL 94Widely‑used North‑American standard for plastic flammability (HB horizontal burn; V‑0/V‑1/V‑2 vertical burn). Its test setup and evaluation criteria are highly analogous to ISO 1210 / IEC 60695‑11‑10.
ASTM D635US horizontal‑burning rate test for plastics (similar to ISO 1210 Method A).
ISO 1210

Plastics; determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source

IEC 60695‑11‑20500 W flame (5V classifications), the "bigger flame" counterpart.
ISO 9773vertical burning of thin flexible films/sheets (for materials that shrink away, which ISO 1210 cannot handle).
ISO 9772cellular plastics, horizontal small‑flame burning.
ASTM D3801vertical, 20 mm flame
ASTM D5048

Higher severity / burn‑through; 125 mm, 500 W flame; 5VA/5VB

ASTM D4804thin flexible
GB/T 2408 (China), AS/NZS 60695.11.10, JIS C 60695‑11‑10, UNE‑EN 60695‑11‑10 — national adoptions of IEC 60695‑11‑10.


Keywords: ASTM D3801 vertical burning tester, solid plastic flammability test machine, vertical flame test for polymers, plastic burning characteristic tester, ASTM D3801 flammability tester, 50W vertical flame test instrument, polymeric material fire test equipment, plastic material combustion lab tester, UnitedTest vertical burning test machine, plastic flammability classification tester

Related products and device

ASTM D3801 UL94 Horizontal & Vertical Flame Tester

UL94 horizontal vertical flame tester, standard UL94 flammability test chamber for plastic, rubber, foam, electronic material fire resistance test, supports HB/V0/V1/V2/5VA/5VB/VTM/HBF test grades, PLC touch screen automatic timing, 50W & 500W dual burner, 1-year full warranty, factory direct export

ISO 4589-2 Plastics burning Oxygen Index Test Apparatus / LOI tester

Oxygen Index Apparatus/LOI tester (Limitation Oxygen Index tester) is widely used to measure burning performance of plastics, rubber, fiber, foam,,film etc., The technique measures the minimum percentage of oxygen in the test atmosphere that is required to marginally support combustion.

Related Standard

ISO 4589-3 High Temperature Oxygen Index Test Temperature Index (TI) and Flammability Temperature (FT) –

ISO 4589-3 — Plastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test. 

ISO 4589-3 defines two core output parameters: Temperature Index (TI) — the minimum oxygen volume fraction sustaining flaming combustion at an elevated test temperature; and Flammability Temperature (FT, Annex A normative method) — the temperature at which a specimen just burns in normal air (20.9 % oxygen).

it takes the classic oxygen-index (OI) test and runs it hot, to answer "how flammable is this plastic when it is already hot?"

ASTM D2863 Oxygen Index Test — LOI Testing for Plastics, Rubber, Foam & Film –

ASTM D2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)

ASTM D2863 measures the Oxygen Index (OI), also called the Limiting Oxygen Index (LOI):

Oxygen Index (OI) — the minimum concentration of oxygen, expressed as volume percent, in a mixture of oxygen and nitrogen that will just support flaming combustion of a material initially at 23 ± 2 °C under the conditions of this test method.

In plain terms: it answers the question "How much oxygen does this plastic need in the air around it to keep burning like a candle?"


Key interpretive benchmark: Ambient air contains ~21 % oxygen. Therefore:

OI ≤ 21 % → the material will continue to burn in normal air

OI > 21 % → the material is self-extinguishing in normal air (higher = more flame retardant)

ISO 9773 Thin Flexible Plastic Vertical Burning Test –

ISO 9773 Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small flame ignition source

ISO 9773 specifies a small‑scale laboratory screening method to evaluate relative burning performance of thin, flexible vertically‑oriented plastic specimens exposed to a low‑energy small‑flame ignition source. These thin flexible samples distort or shrink away from flame in IEC 60695‑11‑10 Method B and cannot be evaluated by that vertical‑burn procedureISO. The test measures afterflame time and afterglow time.

ISO 1210 Plastics Horizontal-Vertical Flammability Burning Test –

ISO 1210 Plastics: determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source

ISO 1210 evaluating the relative burning behaviour of plastic bar specimens exposed to a small‑flame ignition source. It defines two independent test methods: Method A (horizontal burning test) and Method B (vertical burning test). It measures after‑flame time, after‑glow time, damaged length and linear burning rate for comparison of plastic flammability performance. 

IEC 60695-11-10 50W Horizontal & Vertical Flame Test –

IEC 60695-11-10 Fire hazard testing - Part 11-10: Test flames; 50 W horizontal and vertical flame test methods

IEC 60695-11-10 define small‑scale laboratory procedures to compare the burning behaviour of materials used in electrotechnical products, using bar specimens exposed to a 50 W nominal small flame ignition source. It determines either the linear burning rate (Method A) or the self‑extinguishing properties (Method B). Applicable to solid and cellular materials with apparent density > 250 kg/m³ (ISO 845).


ASTM D635 Plastic Horizontal Burning Test –

ASTM D635 Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position

ASTM D635 is a small‑scale laboratory screening procedure for comparing the relative linear rate of burning, or the extent and time of burning (or both), of plastics in bar form — molded or cut from sheets, plates, or panels — tested horizontally. It is a fire‑test‑response method: it measures and describes response to heat and flame under controlled conditions, and it explicitly does not by itself constitute a fire hazard or fire risk assessment.

ASTM D4804 Thin Film Vertical Burning Test –

ASTM D4804 Standard Test Method for Determining the Flammability Characteristics of Nonrigid Solid Plastics

ASTM D4804 is a small‑scale vertical‑burning laboratory test designed for thin, flexible non‑rigid solid plastics that deform, shrink or burn up to clamps when tested by ASTM D3801 (rigid plastic vertical burning). It provides optional VTM‑0/VTM‑1/VTM‑2 classification for flexible thin plastics, and is not intended for building construction or finishing plastics.

Frequently Asked Questions (Q&A) for ASTM D3801 Vertical Burning Test

ASTM D3801 Vertical Burning Tester | UL94 V‑0 V‑1 V‑2 Plastic Flammability Test Chamber – UnitedTest


Q1: What is ASTM D3801 test?

A1: ASTM D3801‑20 is a small‑scale vertical burning test standard for solid plastics. It applies a calibrated 20‑mm (50 W) premixed flame twice to the bottom of vertically‑mounted plastic specimens. It measures afterflame time, afterglow time, flaming dripping behaviour and cotton ignition, to assign V‑0 / V‑1 / V‑2 flammability classification for polymer materials for electrical and appliance components.


Q2: Why is ASTM D3801 important for plastic materials?

A2: It delivers repeatable laboratory flammability comparison data for solid plastics. It evaluates critical fire‑safety risks: self‑extinguishing capability, persistent smouldering (afterglow), and hazardous flaming drips that may ignite surrounding combustibles. It supports material pre‑selection, incoming‑quality control, and R&D screening for electrical device and appliance parts. Note it is only a preliminary lab‑scale indicator; final product safety still depends on full‑equipment certification, not solely D3801 ratings.


Q3: Is ASTM D3801 equal to UL 94 V‑0/V‑1/V‑2 test?

A3: Yes. ASTM D3801 vertical burning test is technically equivalent to ANSI/UL 94 20‑mm (50 W) vertical burning test (V‑0, V‑1, V‑2). It is also equivalent to Test Method B of IEC 60695‑11‑10 (replaces withdrawn ISO 1210). Test data from one standard can be cross‑referenced for these aligned vertical‑burn protocols.


Q4: What specimens can/cannot be tested under ASTM D3801?

A4: ✅ Suitable: rigid solid polymeric plastics for device & appliance components. Non‑plastic non‑metallic samples may run the test but are outside the formal scope. 

❌ Not suitable: building‑construction plastics, wall/floor coverings, furnishings, decorative articles, thin flexible plastic films. Flexible thin sheets should use ASTM D4804 instead. This test does not assess smoke, heat release or hourly fire‑resistance ratings.


Q5: Why does specimen thickness matter for ASTM D3801 results?

A5: Burning performance changes heavily with sample thickness, colour pigments and volatile‑content loss. A V‑0 rating achieved at 3 mm thickness may become V‑2 at 1.5 mm thin gauge. Test results are only valid for the exact specimen thickness and formulation tested. You must test samples at the actual thickness used in your finished product.


Q6: What common mistakes will invalidate ASTM D3801 test results?

A6:

  1. Running test with exhaust fan ON (creates forced draft and distorts flame behaviour).

  2. Using wrong specimen thickness, skipping required pre‑conditioning.

  3. Uncalibrated burner / wrong flame height or power.

  4. Using natural gas instead of referee‑grade methane for disputed tests.

  5. Applying test ratings for building‑construction or flexible‑film applications outside the standard scope.


Q7. What should a lab look for when buying a D3801 tester?

A7: ≥ 0.5 m³ dark, draft‑free chamber; a D5025‑compliant burner with 0°/20°/45° tilt; automatic 10 s timing with ≥150 mm burner retraction; D5207 flame‑confirmation kit; methane gas train with precision flow/pressure control; PLC/touchscreen control with automatic t₁/t₂/t₃ capture; fume extraction with a damper that closes during the test; and fixtures that also cover HB (D635), VTM (D4804) and 5VA/5VB (D5048) so one cabinet serves the whole UL 94 family.


Q8. Why choose ASTM D3801 Vertical Burning Tester from UnitedTest?

A8: UnitedTest is professional manufacturer of ASTM D3801 vertical burning tester for solid plastics. Complies with ASTM D3801‑20, UL 94, IEC 60695‑11‑10 standards for V‑0/V‑1/V‑2 flammability classification. High‑precision lab test chamber for polymer R&D, incoming‑material QC and certification‑lab use.


UnitedTest is a trusted global manufacturer of ASTM D3801 vertical burning test equipment for solid plastic flammability assessment. Our vertical burning test chamber fully complies with ASTM D3801‑20, ANSI/UL 94 vertical burning (V‑0, V‑1, V‑2), and IEC 60695‑11‑10 Test Method B requirements, supporting equivalent‑standard plastic fire‑response laboratory testing for worldwide customers.

Our ASTM D3801 test machine is designed for small‑scale vertical burning characteristic measurement of solid polymeric plastics used in electrical devices, household appliances and electronic component parts. It simulates the standard 20‑mm (50 W) premixed‑flame ignition procedure, accurately recording afterflame time, afterglow time, flaming‑drip behaviour and cotton‑ignition status to generate V‑0 / V‑1 / V‑2 flammability ratings for quality assurance and material pre‑selection.

Core machine features aligned with ASTM D3801‑20 requirements:

  1. Test chamber internal volume ≥ 0.5 m³, dark‑coloured inner surfaces, draft‑free test environment; exhaust fan interlock: exhaust disabled during burning test, activated after test for toxic combustion‑fume removal.

  2. Standard‑compliant laboratory burner per ASTM D5025; supports flame calibration following ASTM D5207 practice for 20‑ mm 50‑W test flame.

  3. Precision timing system with 0.5‑second accuracy for afterflame, afterglow and flame‑impingement timing recording.

  4. Adjustable specimen clamping stand for stable vertical mounting of plastic bar specimens; built‑in observation window for real‑time visual inspection of burning, dripping and cotton‑ignition phenomena.

  5. Gas supply interface supporting technical‑grade methane (referee gas) and natural gas for routine testing.

  6. Built‑in safety protection for lab operators against flame hazards and toxic smoke.

Typical Application Scenarios

UnitedTest ASTM D3801 vertical burning tester is widely deployed in polymer material R&D laboratories, plastic‑product manufacturing QC departments, third‑party certification & testing institutes, and electrical‑appliance component factories. It helps engineers compare relative burning performance among different plastic grades, screen flame‑retardant formulations, perform incoming‑material inspection, and generate lab‑scale flammability data aligned with international standards.

Important note: Test results from ASTM D3801 are comparative small‑scale lab data only. It does not replace full‑product fire‑hazard assessment. Our equipment delivers standard‑compliant test conditions for users to perform testing following ASTM D3801‑20 complete procedure.

UnitedTest supplies standard‑version vertical burning chambers and accepts custom‑configuration requests for lab‑specific requirements. Contact our technical team for quotation, technical specification sheet and application consultation for ASTM D3801 plastic flammability testing solutions.

< Previous: ASTM D3787 Textile Ball Burst Constant Rate Traverse CRT Test

> Next: ASTM D3849 Carbon Black Morphological Characterization by Electron Microscopy

Require More Customized Solutions?

We offer customization to meet your specific needs. Our expert team will collaborate with you to develop the perfect product for you
Customize Now

Beijing United Test Co., Ltd.