Model: MFI404
UNITEDTEST is proud to introduce the MFI series Melt Flow Index Tester/Extrusion Plastometer. They are suitable to measure the melt flow character of PP, PE, PVC, POM, ABS etc., plastic materials resin and granules.
Feature of MFI404-AU:
Large Screen Touching screen; Both MFR/MVR test method; Automatic weight loading system; Motorized cutting and Manual cutting both way; With micro-print; Show the temperature VS Time graph. with otional PC software type. add software and chip update to PC control model.
Principle: The melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) are determined by extruding molten material from the cylinder of a plastometer through a die of specified length and diameter under preset conditions of temperature and load.
General introduction
UNITEDTEST is proud to introduce the MFI series Melt Flow Index Tester/Extrusion Plastometer. They are suitable to measure the melt flow character of PP, PE, PVC, POM, ABS etc., plastic materials resin and granules.
Feature of MFI404-AU:
Large Screen Touching screen; Both MFR/MVR test method; Automatic weight loading system; Motorized cutting and Manual cutting both way; With micro-print; Show the temperature VS Time graph. with otional PC software type. add software and chip update to PC control model.
Principle: The melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) are determined by extruding molten material from the cylinder of a plastometer through a die of specified length and diameter under preset conditions of temperature and load.
Main Features
Large Screen Touching screen;
Both MFR/MVR test method;
Automatic weight loading system;
Motorized cutting and Manual cutting both way;
With micro-print;
Show the temperature VS Time graph.
with otional PC software type. add software and chip update to PC control model.
This model is a fully automatic model, which drives the ball screw to rotate through the stepper motor to achieve the purpose of automatically controlling the top loading weight to rise or fall;

Approximately 7 grams of the material is loaded into the barrel of the melt flow apparatus, which has been heated to a temperature specified for the material. A weight specified for the material is applied to a plunger and the molten material is forced through the die. A timed extrudate is collected and weighed. Melt flow rate values are calculated in g/10 min.
Specimen size:
At least 14 grams of material;
Test Data:
Flow rate = ( 600/t x weight of extrudate )
t = time of extrudate in seconds
melt flow rate = g/10 min.
ISO 1133 Plastics - Determination of the Melt Mass-Flow Rate (MFR) and Melt Volume-Flow Rate (MVR) of Thermoplastics
ASTM D1238 Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer
ASTM D3364 (for PVC), BS 2782, DIN 53735, JIS K7210
1, Built-in temperature stability prompt alarm, and add GB/T3682 specified 300 seconds/240 seconds material preheating second countdown, after the countdown is over, the mention will be issued signaling, you can also set the American standard ASTM D1238 and other warm-up time;
2, 3-stage temperature control mode, 3 sets of platinum resistance sensors, 3 heating sleeves for separate temperature control, high-precision intelligent PID control, heating slope that is, heating speed can be adjusted;
3, Built-in a variety of plastic material melt flow index test conditions, easy for customers to access and use at any time, reduce the tedious workload, and store the last test conditions and results;
4, Sensitive 7-inch touch screen controller, which can store and list the latest test conditions and data, and the test printing menu can be set including the test time (system default), operator, material name, test method, test conditions (temperature, weight weights, cutting time interval), test result data, measurement The test result is artificially judged to be OK or NG, etc.;
5, RS232 interface or USB interface is reserved to connect to the computer, which can control the operation of the instrument and transmit the test data to the computer;
6, Support all international test standards and methods, including ISO 1133, ASTM D1238, ASTM D3364, GB/T3682 and other national standards or international standards organization standards.
Main technical specification
| Model | MFI404-AU |
| Temperature range | Ambient temperature to 450℃ stepless adjustable, fixed point temperature control |
| Display mode | Touching Screen display |
| Loading method | Automatic |
| Temperature fluctuation | ±0.2℃ |
| Temperature resolution | 0.1℃ |
| transducer accuracy (in mm) | resolution 0.001mm/ accuracy 0.01mm |
| time resolution (in seconds) | resolution 0.001s / accuracy 0.01s |
| Weight | 1: 1.200 kg=(0.325+ No. 2 weight 0.875kg)=11.77 N 2: 2.160 kg=(0.325+No. 3 weight 1.835kg)=21.18 N 3: 3.800 kg=(0.325+ No.4 weight 3.475kg)=37.26 N 4: 5.000 kg=(0.325+ No.5 weight 4.675kg)=49.03 N 5: 10.000 kg=(0.325+No. 5 weight 4.675kg + No. 6 weight 5.000Kg )=98.07 N 6: 12.500 kg=(0.325+No.5 weight 4.675kg + No.6 weight 5.000kg + No.7 weight 2.500kg)=122.58 N 7: 21.600 kg=(0.325+No.2 weight 0.875kg+No3.weight 1.835kg + No.4 weight 3.475kg+No.5 weight 4.675kg + No.6 weight 5.000kg + No.7 weight 2.500kg+No.8 weight 2.915kg)=211.82 N |
| Measuring method & range | MFR (0.1-100) g/10min; MVR (0.1-3500) cm3/10min |
| Heating power | 450W |
| Counting time | 0~6000s |
| Countdown time setting | Can free setting(300s/240s) |
| Inner diameter of die | φ2.095±0.005mm |
| Length of die | 8.000±0.025mm |
| Inner diameter of filling canister | Φ9.550±0.007mm |
| Weight | Frame: 130k gStandard weights: 160kg |
| Power | 220V, 50HZ/110V, 60HZ |
| Printer | YES, A4 printer |
| Specimen cutting mode | Automatic & Manual both modes |
Main Accessories
| Item | Quantity |
|---|---|
| Frame | 1 set |
| Die (φ2.095) tungsten carbide material | 1 pc |
| No. 1 weight (piston rod + weight tray): 325g | 1 pc |
| No. 2 weight: 875g | 1 pc |
| No. 3 weight: 1835g | 1 pc |
| No. 4 weight: 3475g | 1 pc |
| No. 5 weight: 4675g | 1 pc |
| No. 6 weight: 5000g | 1 pc |
| No. 7 weight: 2500g | 1 pc |
| No. 8 weight: 2915g | 1 pc |
| Scraper | 1 pc |
| Sample loading hopper | 1 pc |
| Water level | 1 pc |
| Die cleaning rod | 1 pc |
| Cylinder cleaning rod | 1 pc |
| Sample loading rod | 1 pc |
| Sample plate | 1 pc |
| Electric wire | 1 pc |
| Cleaning gauze and gloves | 1 pc |
| Accessories containing case | 1 pc |
| Documents (Manual, packing list, certificate) | |
Require More Customized Solutions?