Your current locationHome>Application>Standard>ISO>Plastic
Application
Plastic
ISO 9852 Dichloromethane resistance test
Date:2025-08-10 Source:United Test Views:100

ISO 9852 Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method


ISO 9852 specifies a method for determining the resistance of unplasticized poly(vinyl chloride) (PVC-U) pipes to dichloromethane at a specified temperature (DCMT). It is applicable to all PVC-U pipes, irrespective of their intended use.


Scope of application

  • Suitable for any homogeneous flat-walled, unplasticized PVC pipe, regardless of its intended use

  • It can be used as a means of rapid quality control in the production process

  • It is especially suitable for quality inspection and performance evaluation of PVC-U pipes

Technical content and testing methods

Core test principles

The ISO 9852 standard specifies a method for determining the resistance of PVC-U pipes to methylene chloride at specified temperatures (DCMT). This method evaluates the plasticization uniformity and internal structural integrity of the pipe specimen by immersing the pipe specimen in methylene chloride solution and observing the degree of damage to the surface of the pipe after impregnation.


Key test parameters:

parameter

Technical    requirements:

remark

Test   temperature

T±0.5℃(≥12℃)

Common   15°C, 20°C or 30°C

Soaking   time

30±1   min

Strict   control

Sample   preparation

Choose   the chamfer angle according to the wall thickness (10°-30°)

Avoid   mechanical heating

Thickness   of the water sealing layer

≥20mm

Reduces   reagent evaporation


Dichloromethane resistance test Equipment configuration requirements

The test system must include the following key components:

  • Stainless steel/glass containers: equipped with double grids (dip bit/drip level)

  • Temperature control system: accuracy ± 0.5°C

  • Ventilation system: meets methylene chloride vapor threshold limit (TLV 100ppm)

  • Protective Gear: Includes gloves and goggles


Relationship with GB/T 13526

The Chinese national standard GB/T 13526-2007 "Test Method for Dichloromethane Impregnation of Rigid Polyvinyl Chloride (PVC-U) Pipes" is equivalent to ISO 9852:2007 international standard. The two are highly consistent in terms of technical content, and the main correspondence is as follows:

  1.  Specimen specifications: all are 160mm length (100mm for the 1995 version of ISO      standard).

  2.  Impregnation time: 30 minutes (20 minutes for GB/T 13526-1992).

  3.  Judgment method: The qualitative determination of the degree of failure, the percentage of failure of the inclined surface and the percentage of failure in the      circumferential direction are calculated

  4.  Specimen angle: Determine the inclination angle according to the wall thickness of the pipe


Beijing United Test Co.,Ltd. export@unitedtest.com offer the testing equipment of ISO 9852 Dichloromethane resistance test. Contact us now : export@unitedtest.com, unitedtest@hotmail.com

Related products
Contact

Email:
export@unitedtest.com
unitedtest@hotmail.com
Tel:
+86-10-57055071
+86-13911165373

MS Teams: 
unitedtest@hotmail.com

WhatsApp:
+86 13911165373

WeChat:
UnitedTest-V1 

X