Information on the most widely used ASTM standards within the materials testing industry
ASTM C473: Standard Test Methods for Physical Testing of Gypsum Panel Products
The ability of gypsum panel products to resist nail pull-through is evaluated by determining the loaded required to push a standard nail head through the product. The humidified deflection of gypsum panel products are evaluated by supporting a specimen that has been cut with the long dimension perpendicular to the machine detection, supported horizontally, and subjected to high humidity.
ASTM C473 test methods cover the physical testing of gypsum panel products.
Mainly test methods include in ASTM C473:
| (1) flexural strength (Method A); |
| (2) core, end, and edge hardness (Method A); |
| (3) nail pull resistance (Method A); |
| (4) humidified deflection; |
| (5) end squareness; |
| (6) water resistance of core-treated water repellant gypsum panel products; |
| (7) surface water resistance of gypsum panel products with water-repellant surfaces. |
Key words:
absorption testing; core hardness testing; dimension measurements; edge hardness testing; end hardness testing; flexural strength; gypsum panel products; humidified sag; nail pull testing